Journal of South China University of Technology (Natural Science Edition) ›› 2006, Vol. 34 ›› Issue (6): 112-116.

• Electric Engineering • Previous Articles     Next Articles

Design and Implementation of Optimized Dispatching Software System for Unit Load in Thermal Power Plant

Ma Xiao-qian  Wang Yi  Liao Yan-fe   

  1. College of Electric Power,South China Univ.of Tech.,Guangzhou 510640,Guangdong,China
  • Received:2005-06-16 Online:2006-06-25 Published:2006-06-25
  • Contact: 马晓茜(1964-),男,教授,博士生导师,主要从事电厂运行优化与控制、高效低污染燃烧方面的研究. E-mail:epxqma@scut.edu.cn
  • About author:马晓茜(1964-),男,教授,博士生导师,主要从事电厂运行优化与控制、高效低污染燃烧方面的研究.

Abstract:

In order to reduce the energy cost of thermal power plants,the architecture of a real.time optimized dispatching software system based on SIS(Supervisory Information System)platform is presented for unit load,in which the tight integration of SIS and MIS(Management Information System)and the auto-dispatching of the load are implemented.The real-time characteristic curves describing the energy cost of each unit are then simulated by the on-line collection and economic calculation of the operating data,with a mathematical model of load dispatching being set up.According to the proposed model,the optimized dispatching of the load is realized via the layered fuzzy genetic algorithm.Moreover,the corresponding dispatching software system is designed and implemented based on the Microsoft.NET Framework and the multi-layer Browser/Server concept.As compared with the traditional onduty dispatching mode,the proposed softwaFe helps decrease the power-supply coal cost rate by 0.5 g/(kW ·h), thus reducing the energy cost.

Key words: thermal power plant, load, optimized dispatching, supervisory information system , layered fuzzy ge-netic algorithm