Journal of South China University of Technology (Natural Science Edition) ›› 2021, Vol. 49 ›› Issue (10): 114-122.doi: 10.12141/j.issn.1000-565X.200709

Special Issue: 2021年能源、动力与电气工程

• Energy, Power & Electrical Engineering • Previous Articles     Next Articles

Experimental Study on Enhanced Heat Transfer Characteristics of Plate Condenser with Liquid-Vapor Separation

YAO Yuan1,2,3 CHEN Ying2 CHEN Jianyong2 LIANG Zhiying2   

  1. 1. Guangzhou Institute of Energy Conversion,Chinese Academy of Science,Guangzhou 510640,Guangdong,China; 2. School of Materials and Energy,Guangdong University of Technology,Guangzhou 510006,Guangdong,China; 3. Key Laboratory of Renewable Energy,Chinese Academy of Sciences,Guangzhou 510640,Guangdong,China
  • Received:2020-11-17 Revised:2020-12-28 Online:2021-10-25 Published:2021-09-30
  • Contact: 陈颖 ( 1969-) ,女,教授,博士生导师,主要从事空调及热能动力研究。 E-mail:chenying@gdut.edu.cn
  • About author:姚远 ( 1976-) ,男,在职博士生,高级工程师,主要从事热泵及换热器强化换热研究。E-mail:yaoyauan@ms.giec.ac.cn
  • Supported by:
    Supported by the Regional Key Projects of Science and Technology Service of Chinese Academy of Sciences ( KFJ-STS-QYZX-114) and the Key Projects of Scientific and Technological Innovation in Shandong Province ( 2019JZZY010910)

Abstract: A new type of plate condenser which can discharge condensate in the middle was designed. The drain port was set in the middle of the condenser,which can speed up the drainage,reduce the thickness of the condensate film attached to the plate,reduce the thermal resistance of the liquid film between the vapor and the plate,and increase the phase change heat transfer coefficient of the plate condenser. The performance of the liquid-vapor separation plate condenser ( LVSPC) was compared with that of the conventional plate condenser ( CPC) . The experimental results of 10 different test conditions show that,under the same initial conditions,compared with the CPC, the condensation heat transfer coefficient of the LVSPC is increased by 8. 3% ~51. 6%,the total heat transfer coefficient is increased by 7. 6% ~ 38. 3% ,and the total pressure drop is reduced by 2. 6% ~ 11. 4% . The experimental results proved that the LVSPC can achieve the purpose of enhancing heat transfer and reducing pressure drop. However,due to the decrease of working fluid flow in the second condensing area,the total heat transfer of the LVSPC is approximately equal to that of CPC,and there is no obvious increase.

Key words: plate condenser, liquid-vapor separation, enhanced heat transfer, pressure drop, heat transfer coefficient

CLC Number: