Circuit of High Frequency Charge Pump Power-factor- correction Technique with Soft-switching

ZHANG Zhuzheng XIE Yunxiang LU Zhuqiang   

  • Online:2003-06-20 Published:2022-09-07
  • Contact: 张祖正(1977一),男,硕士研究生,主要从事电 力电子及电气传动研究。
  • About author:张祖正(1977一),男,硕士研究生,主要从事电 力电子及电气传动研究。

Abstract: The charge pump concept for achieving power-factor-correction (PFC) and its unity power factor condition are analyzed. A kind of high frequency charge pump PFC circuit is proposed in this paper. The principle of the circuit and soft-switching are discussed. The simulation and experimental results show that unity power factor and low total harmonic distortion (THD) can be achieved for the use of the circuit in electronic ballast, which proves that the performance of high frequency charge pump power factor correction is optimal.

Key words: charge pump, power-factor-correction, soft-switching