Journal of South China University of Technology (Natural Science Edition) ›› 2015, Vol. 43 ›› Issue (12): 77-84.doi: 10.3969/j.issn.1000-565X.2015.12.011

• Traffic & Transportation Engineering • Previous Articles     Next Articles

Investigation into Prestress Loss of Short Straight Tendons in Pylon Anchorage Zone of Cable-Stayed Bridge

Cui Nan-nan Jia Bu-yu Yu Xiao-lin Yang Zheng Yan Quan-sheng   

  1. School of Civil Engineering and Transportation,South China University of Technology,Guangzhou 510640,Guangdong,China
  • Received:2015-05-07 Revised:2015-09-17 Online:2015-12-25 Published:2015-11-01
  • Contact: 贾布裕(1983-),男,博士,助理研究员,主要从事复杂桥梁结构分析、大跨度桥梁可靠度研究等. E-mail:ctjby@ scut.edu.cn
  • About author:崔楠楠(1987-),女,博士生,主要从事预应力混凝土结构设计方法研究.E-mail: annatreecivile@sohu.com
  • Supported by:
    Suppouted by the Nation Natural Science Foundation of China(51478193,51208208) and the China Postdoctoral Science Foundation(2013M542174)

Abstract: As the way of arranging circular prestress tendons in the PC (Prestressed Concrete) pylon anchorage zones of cable-stayed bridges has its disadvantages in terms of mechanical performance and construction,a new arrangement of prestress tendons by the name of one-way straight tendons is put forward. Under this kind of arrangement,the prestress tendons are relatively short,and their prestress loss laws and construction control are different from the tendons with common length. In order to investigate the loss characteristic of this kind of short straight prestress tendons,the friction loss (the duck friction and the anchorage friction) and the loss due to anchorage set as well as the elongation control are emphatically analyzed by a full-scale model test. Moreover,the prestress tendons under anchor are observed for a short time. The results show that (1) the average total loss of prestress is 26%;(2) in the total loss,the loss due to anchorage set,the duct friction loss and the anchorage head friction loss respectively account for more than 50%,about 12% and 20%,and the latter two types of loss should not be ignored as most articles and codes have recommended; and (3) the elongation control is still applicable in the construction of short prestress tendons,but in view of its exquisite sensitivity to the construction error,the construction quality must be guaranteed and the permissible error should be extended to ±9%.

Key words: prestressed concrete, pylon anchorage zone, short straight prestress tendons, prestress losses, construction, test study