Journal of South China University of Technology (Natural Science Edition) ›› 2014, Vol. 42 ›› Issue (5): 90-96.doi: 10.3969/j.issn.1000-565X.2014.05.014

• Traffic & Transportation Engineering • Previous Articles     Next Articles

Influence of Pipe- Burying Mode on Hydrothermal Snow Melting of Bridge Decks

Fu Zhen1 Wang Xuan- cang2 Lu Kai- quan2   

  1. 1.School of Materials Science and Engineering,Chang'an University,Xi'an 710064,Shaanxi,China;2.School of Highway,Chang'an University,Xi'an 710064,Shaanxi,China
  • Received:2013-11-14 Revised:2014-02-11 Online:2014-05-25 Published:2014-04-01
  • Contact: 傅珍(1976-),女,博士,副教授,主要从事道路材料研究. E-mail:fuzhen524@sina.com
  • About author:傅珍(1976-),女,博士,副教授,主要从事道路材料研究.
  • Supported by:

    国家自然科学基金资助项目(51108038, 51108039);长安大学中央高校基本科研业务费专项资金资助项目(CHD2012ZD016);陕西省科技厅项目(2013KW24, 2013kjxx-94)

Abstract:

In this paper,first,a numerical model was established with finite element program.Then,a thermody-namic simulation on the snow melting process of bridge decks in steady state was made by means of finite differencemethod.Finally,by taking mountain thermal spring water as a hot fluid medium,the influences of pipe- buryingdepth and pipe spacing on the temperature distribution and heat flux density of bridge decks were investigated at anambient temperature of -5℃,a surface wind speed of 2m/s and a water temperature of 15℃.The results showthat (1) there are dense isotherms and high heat flux density around buried pipes; (2) both pipe- burying depthand pipe spacing produce great impact on the distribution uniformity of deck surface temperature and heat flux den-sity; and (3) smaller pipe- burying depth and pipe spacing may result in higher deck surface temperature as well asheat flux density,and may accelerate snow melting and its velocity.Therefore,considering such comprehensivefactors as snow melting effect,construction and economy.it is suggested that pipe- burying depth should be 2 cmand pipe spacing should be 15cm.

Key words: highway engineering, bridge decks, hydrothermal snow melting, pipe- burying depth, pipe spacing