华南理工大学学报(自然科学版) ›› 2008, Vol. 36 ›› Issue (10): 6-11.

• 土木建筑工程 • 上一篇    下一篇

转换层结构楼层侧向刚度的有害位移角控制法

韩小雷 何慧贤 田小霞 季静 郑宜   

  1. 华南理工大学 亚热带建筑科学国家重点实验室, 广东 广州 510640
  • 收稿日期:2007-09-10 修回日期:2007-12-10 出版日期:2008-10-25 发布日期:2008-10-25
  • 通信作者: 韩小雷(1964-),男,教授,博士生导师,主要从事高层建筑结构设计理论与实践研究. E-mail:xlhan@seut.edu.cn
  • 作者简介:韩小雷(1964-),男,教授,博士生导师,主要从事高层建筑结构设计理论与实践研究.
  • 基金资助:

    广东省自然科学基金资助项目(06105416)

Control of Lateral Stiffness with Harmful Drift Angle for Structure with Transfer Storey

Han Xiao-lei  He Hui-xian  Tian Xiao-xia  Ji Jing  Zheng Yi   

  1. State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640, Guangdong, China
  • Received:2007-09-10 Revised:2007-12-10 Online:2008-10-25 Published:2008-10-25
  • Contact: 韩小雷(1964-),男,教授,博士生导师,主要从事高层建筑结构设计理论与实践研究. E-mail:xlhan@seut.edu.cn
  • About author:韩小雷(1964-),男,教授,博士生导师,主要从事高层建筑结构设计理论与实践研究.
  • Supported by:

    广东省自然科学基金资助项目(06105416)

摘要: 提出采用有害位移角来控制带转换层高层建筑结构的侧向刚度.通过对大量不同结构布置、不同剪力墙厚度的带转换层的高层建筑结构的计算分析,将楼层有害位移角比小于等于0.9作为带转换层的高层建筑结构楼层侧向刚度的控制准则.同时,采用有限元计算模型分析了转换层上下部剪力墙刚度、转换梁刚度、转换层层高等因素对杆系模型的有害位移角计算的影响,得出了修正的有害位移角比值法,并提出了工程应用建议.

关键词: 转换层, 高层建筑, 侧向刚度, 有害位移角

Abstract:

This paper introduces a harmful drift angle transfer storey. Based on numerous sample analyses of to control the lateral stiffness of high-rise structures with high-rise buildings with transfer storey and by considering the effects of various different kinds of structures and different shear wall thicknesses, an appropriate harmful drift angle ratio of no more than 0.9 is put forward as the control criterion of the lateral stiffness of high-rise buildings with transfer storey. Moreover, by employing a finite element model, the influences of such factors as the inter-storey shear wall stiffness, the transfer beam stiffness and the storey height on the harmful drift angle calculated by the link model are analyzed. Thus, a modified harmful drift angle ratio method is obtained. Some suggestions are also made for engineering applications.

Key words: transfer storey, high-rise building, lateral stiffness, harmful drift angle