Power & Electrical Engineering

State Analysis of Induction Motor Based on CF-SOM-MQE Under Unbalanced Sample Condition

Expand
  •  1. School of Electric Power,South China University of Technology,Guangzhou 510640,Guangdong,China; 2. State Grid Hebei Electric Power Co. ,Ltd. ,Cangzhou Power Supply Branch,Cangzhou 061000,Hebei,China
王磊( 1987-) ,男,博士生,主要从事感应电机故障诊断研究

Received date: 2018-05-14

  Revised date: 2018-08-22

  Online published: 2019-01-31

Supported by

 Supported by the Natural Science Foundation of Guangdong Province( 2016A030313464)

Abstract

To improve the accuracy of induction motor state evaluation,a model based on correlation algorithm ( CF) and self-organizing map minimum quantization error ( SOM-MQE) was proposed to solve the problem of fundamental current signal interference and lack of fault data. Firstly,the autocorrelation algorithm and cross-correlation algorithm theory were briefly introduced. The characteristic harmonic components in the stator current were analyzed and input into the SOM neural network as performance degradation indicators. Based on this,the minimum quantization error ( MQE) value was calculated. MQE was used as a measure of condition monitoring of induction motors. The example shows that the proposed model can accurately estimate the health status of induction motors,so it has strong engineering application value and versatility.

Cite this article

WANG Lei LIU Yongqiang . State Analysis of Induction Motor Based on CF-SOM-MQE Under Unbalanced Sample Condition[J]. Journal of South China University of Technology(Natural Science), 2019 , 47(3) : 30 -36,92 . DOI: 10.12141/j.issn.1000-565X.180228

References

 
Outlines

/