Architecture & Civil Engineering

Investigation into Half Grout Sleeve Splicing for Rebars via Static Tensile Test

  • HUANG Yuan ,
  • ZHU Zheng-Geng ,
  • HUANG Deng ,
  • YI Wei-Jian ,
  • ZHANG Rui
Expand
  • College of Civil Engineering,Hunan University,Changsha 410082,Changsha,China
黄远(1982-) ,男,博士,副教授,主要从事组合结构及装配式结构研究.

Received date: 2015-04-24

  Revised date: 2015-08-14

  Online published: 2016-01-04

Supported by

Supported by the National Natural Science Foundation of China( 51478174, 51338004) and the Natural Science Foundation of Hunan Province( 14JJ3054)

Abstract

In order to investigate the mechanical properties of half grout sleeve splicing for rebars,14 specimens were tested under static tension,with such main parameters as bar diameter,sleeve dimension and rebar deviation being considered.The results show that ( 1) the tested half grout sleeves meet the strength requirements well; ( 2) the specimens are destroyed in three failure patterns including the tension fracture of the rebar,the rebar scratchplough pulling out of the rebar and the sliding wire of the sleeve; and ( 3) when the tension fracture of the rebar occurs,the rebar deviation has little effect on the bearing capacity of specimens.Based on the analysis of the test results,a design method is put forward to avoid the occurrence of the rebar scratch-plough pulling out and the sleeve sliding wire.

Cite this article

HUANG Yuan , ZHU Zheng-Geng , HUANG Deng , YI Wei-Jian , ZHANG Rui . Investigation into Half Grout Sleeve Splicing for Rebars via Static Tensile Test[J]. Journal of South China University of Technology(Natural Science), 2016 , 44(2) : 26 -32 . DOI: 10.3969/j.issn.1000-565X.2015.02.005