Power & Electrical Engineering

Improved Composite Control of Grid-Connected Inverter

Expand
  • School of Electric Power,South China University of Technology,Guangzhou 510640,Guangdong,China
桂存兵(1974-),男,博士,副教授,主要从事电力电子技术在电力系统中的应用研究.

Received date: 2014-09-29

  Revised date: 2015-03-12

  Online published: 2015-07-01

Supported by

Supported by the Project of Integration of Industry,Education and Research of Guangdong Province and Ministry of Education of China(2011B090400136)

Abstract

The LCL filter is a third-order system of a low damping,where resonanceis easy to occur. Aiming at the
issue,this paper adopts a dual-loop control strategy with the grid-connected current feedback and the capacitor current feedback to control the grid-connected current,and then designs a novel repetitive controller,which possesses a modified self-adaptive internal model and is plugged in the system. This repetitive controller is combined with the traditional PI control to form a new improved composite control scheme,thus improving the working stability of the LCL filter,minimizing the current harmonic distortion and increasing the performance of the grid-connected inverter. Finally,the feasibility and superiority of the improved scheme are verified by simulations and experiments. Besides,whether the voltage frequency of power systems changes or not,the improved scheme can effectively avoid the resonance of grid currents and can achieve a high in-grid power factor.

Cite this article

Gui Cun-bing Xie Yun-xiang Cheng Li Wang Yu . Improved Composite Control of Grid-Connected Inverter[J]. Journal of South China University of Technology(Natural Science), 2015 , 43(8) : 15 -20 . DOI: 10.3969/j.issn.1000-565X.2015.08.003

References

[1] Twining E,Holmes D G.Grid current regulation of a three-phase voltage source inverter with an LCL input filter[J].IEEE Transactions on Power Electronics,2003,18(3):888-895. [2] 王要强,吴凤江,孙力,等.阻尼损耗最小化的 LCL滤波器参数优化设计[J].中国电机工程学报,2010, 30(27):90-95. Wang Yaoqiang, Wu Fengjiang, Sun Li, et al. Optimized design of LCL filter for minimal damping power loss[J]. Proceedings of the CSEE,2010,30(27):90-95(in Chinese). [3] Tang Yi,Loh P C,Wang Peng,et al.Exploring inherent damping characteristic of LCL-filters for three-phase grid-connected voltage source inverters[J]. IEEE Trans. on Power Electronics,2012,27(3):1433-1443. [4] Dannehl J,Fuchs F W,Hansen S,et al.Investigation of active damping approaches for PI-based current control of grid-connected pulse width modulation converters With LCL filters[J].IEEE Trans. on Industry Applications, 2010,46(4):1509-1517. [5] 彭双剑,罗安,荣飞,等.LCL 滤波器的单相光伏并网控制策略[J]. 中国电机工程学报, 2011, 31(21): 17-24. Peng Shuangjian,Luo An,Rong Fei,et al.Single-phase photovoltaic grid-connected control strategy with LCL filter[J]. Proceedings of the CSEE, 2011, 31(21): 17-24(in Chinese). [6] 徐志英,许爱国,谢少军.采用 LCL 滤波器的并网逆变器双闭环入网电流控制技术[J].中国电机工程学报, 2009,29(27):36-41. Xu Zhiying,Xu Aiguo,Xie Shaojun.Dual-loop grid current control technique for grid-connected inverter using an LCL filter[J]. Proceedings of the CSEE, 2009, 29(27): 36-41(in Chinese). [7] 王要强,吴凤江,孙力,等.带 LCL 输出滤波器的并网逆变器控制策略研究[J].中国电机工程学报,2011, 31(12):34-39. Wang Yaoqiang,Wu Fengjiang,Sun Li,et al.Control strategy for grid-connected inverter with an LCL output filter[J]. Proceedings of the CSEE, 2011, 31(12): 34-39(in Chinese). [8] 许津铭,谢少军,肖华锋.LCL 滤波器有源阻尼控制机制研究[J].中国电机工程学报,2012,32(9):27-33. Xu Jinming,Xie Shaojun,Xiao Huafeng.Research on control mechanism of active damping for LCL filters[J]. Proceedings of the CSEE, 2012, 32(9): 27-33(in Chinese). [9] 张强, 张崇巍, 张兴, 等. 风力发电用大功率并网逆变器研究[J]. 中国电机工程学报,2007,27(16):55-59. Zhang Qiang,Zhang Chongwei,Zhang Xing,et al.Study on grid-connected inverter used in high-power wind generation system [J].Proceedings of the CSEE,2007,27(16):55-59(in Chinese). [10] 沈国桥,徐德鸿.LCL 滤波并网逆变器的分裂电容法电流控制 [J].中国电机工程学报,2008,28(18):36-41. Shen Guoqiao,Xu Dehong.Current control for grid-connected inverters by splitting the capacitor of LCL filter[J]. Proceedings of the CSEE,2008,28(18):36-41(in Chinese). [11] 谢川,张靖等. 适于重复控制固定采样点数的数字锁相方法[J]浙江大学学报,2011,45(5):789-793. Xie Chuan,Zhang Jing, et al.Digital PLL with fixed number of sampling points for repetitive control algorithm [J].Journal of Zhejiang University(Engineering Science)N,2011,45(5):789-793. [12] Lee K J, Park N J, Kim R Y, et al. Design of an LCL filter employing a symmetric geometry and its control in grid-connected inverter applications[C].IEEE PESC,Rhodes,Greece,2008. [13] 陈东,张军明,钱照明.带 LCL 滤波器的并网逆变器单电流反馈控制策略[J]. 中国电机工程学报,2013,33(9):10-16 CHEN Dong, ZHANG Junming, QIAN Zhaoming. Single Current Feedback Control Strategy for Grid-connected Inverters With LCL Filters[J].Proceedings of the CSEE,2013,33(9):10-16(in Chinese). [14] 陈伯时.电力拖动自动控制系统:运动控制系统[M].北京:机械工业出版社,2003:56-76. [15] 秦 喆, 苏建徽, 刘骏亚等. 一种新型并网逆变器重复电流控制策略的研究[J].低压电器,2013,11:32-36 QIN Zhe, SU Jianhui, LIU Junya, LIANG Huanyu, et al.Research of a Novel Control Method for Repetitive Current Control of Grid- Connected Inverter [J].LOW VOLTAGE APPARATUS,2013,11:32-36. [16] ZHOU KELIANG, WANG D Digital repetitive controlled three-phase PWM rectifier[J] Powei Electronics, IEEE Transactions on 2003,18 309-316
Outlines

/