Journal of South China University of Technology (Natural Science Edition) ›› 2009, Vol. 37 ›› Issue (2): 147-151.

• Power & Electrical Engineering • Previous Articles     Next Articles

Buck DC-AC Inverter Based on Double-Loop Control

Chen Jiang-hui  Xie Yun-xiang  Huang Min-jun  Ming Zong-feng  Chen Jing-feng    

  1. School of Electric Power, South China University of Technology, Guangzhou 510640, Guangdong, China
  • Received:2007-12-11 Revised:2008-05-22 Online:2009-02-25 Published:2009-02-25
  • Contact: 陈江辉(1975-),男,博士生,主要从事电力电子装置及车载逆变电源研究. E-mail:jianghuichen@tom.com
  • About author:陈江辉(1975-),男,博士生,主要从事电力电子装置及车载逆变电源研究.
  • Supported by:

    广东省自然科学基金资助项目(05006521)

Abstract:

In order to improve the dynamic characteristics, robustness and anti-disturbance performance of Buck DC-AC inverters, a double-loop controller with current feedforward is presented. In this controller, the full-state feedback scheme is adopted to implement the double-loop control of voltage and current, thus improving the dynamic response as well as the steady-state performance of the inverter system. Moreover, a current feedforward loop is em- ployed to improve the anti-disturbance performance of the inverter system. Experimental results indicate that the inner loop in the double-loop controller enlarges the bandwidth of the inverter control system, quickens the dynamic response, increases the steady-state precision, and restrains the load turbulence.

Key words: Buck converter, double-loop control, inverter, dynamic response