Influence of Bond Length on Bonded Interface Performance of CFRP-C60 Concrete

HONG Lei DUO Run-min WANG Su-yan   

  1. State Key Laboratory of Coastal and Offshore Engineering,Dalian University of Technology,Dalian 116024,Liaoning,China
  • Received:2015-03-26 Revised:2015-09-18 Online:2016-02-25 Published:2016-01-04
  • Contact: 洪雷(1964-) ,男,博士,副教授,主要从事FRP 加固混凝土结构研究. E-mail:honglei_a@163.com
  • About author:洪雷(1964-) ,男,博士,副教授,主要从事FRP 加固混凝土结构研究.
  • Supported by:
    Supported by the National Natural Science Foundation of China( 51378089)

摘要: 通过自行设计的加载装置,采用双面剪切试验法研究了粘结长度对碳纤维增强复合材料( CFRP) -C60 高强混凝土界面性能的影响,并提出了最小粘结长度的概念和有效粘结长度模型. 结果表明: 随粘结长度的增大,试件破坏时的极限荷载和极限位移均显著增加,但初始剥离荷载和初始剥离位移都没有明显的变化; 随着荷载的增加,应力的传递区域不断向前推进,同时应力传递区域的长度也不断增加,即应力传递区域呈现动态变化; C60 混凝土的最小粘结长度大约为有效粘结长度的2 倍,只有当粘结长度大于最小粘结长度时才可充分发挥粘结界面的承载力,提高界面延性.

关键词: 碳纤维增强复合材料, 高强混凝土, 界面性能, 粘结长度, 双面剪切试验

Abstract: By using a self-designed loading device,the interface performance of CFRP ( Carbon Fiber-Reinforced Polymer) -C60 high-strength concrete under different bond lengths are investigated via double shear tests.Then,the concept of the minimum bond length is proposed and a model of the effective bond length is established.The results indicate that ( 1) with the increase of the bond length,both the ultimate bond load and the ultimate global slip response increase remarkably ,while the initial strip load and the initial strip response have no significant change; ( 2) with the increase of the load,the stress transfer area moves forward from the loading end and continuously prolongs,which presents a process of dynamic change; ( 3) the minimum bond length of C60 concrete is about 2 times the effective bond length; and ( 4) when the bond length is larger than the minimum value,the bearing capacity of the concrete can be fully used and the ductility is improved.

Key words: carbon fiber-reinforced polymer, high-strength concrete, interface performance, bond length, double shear test