华南理工大学学报(自然科学版) ›› 2014, Vol. 42 ›› Issue (10): 110-116.doi: 10.3969/j.issn.1000-565X.2014.10.018

• 土木建筑工程 • 上一篇    下一篇

不同板中配筋形式下板柱结构的连续倒塌性能

杨涛1,2 蓝文武1† 钱凯3   

  1. 1. 广西大学 土木建筑工程学院, 广西 南宁 530004; 2. 广西大学 广西防灾减灾与工程安全重点实验室, 广西 南宁 530004;3. 新加坡南洋理工大学 自然灾害研究中心, 新加坡 639798
  • 收稿日期:2014-03-25 修回日期:2014-06-23 出版日期:2014-10-25 发布日期:2014-10-01
  • 通信作者: 蓝文武(1966-),男,博士,副教授,主要从事组合结构与工程抗震研究. E-mail:lanwenwu@gxu.edu.cn
  • 作者简介:杨涛(1979-),男,博士,讲师,主要从事混凝土结构和组合结构研究.E-mail:yt48440002@163.com
  • 基金资助:

    国家自然科学基金资助项目(51368006);广西防灾减灾与工程安全重点实验室系统性研究项目(2014ZDX02)

Progressive Collapse Performance of Flat Slab Structures with Different Slab Reinforcement Details

Yang Tao1,2  Lan Wen-wu1  Qian Kai3   

  1. 1. College of Civil Engineering and Architecture, Guangxi University, Nanning 530004, Guangxi, China; 2. Guangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, Guangxi, China;3. Natural Hazards Research Center, Nanyang Technological University, Singapore 639798
  • Received:2014-03-25 Revised:2014-06-23 Online:2014-10-25 Published:2014-10-01
  • Contact: 蓝文武(1966-),男,博士,副教授,主要从事组合结构与工程抗震研究. E-mail:lanwenwu@gxu.edu.cn
  • About author:杨涛(1979-),男,博士,讲师,主要从事混凝土结构和组合结构研究.E-mail:yt48440002@163.com
  • Supported by:

    国家自然科学基金资助项目(51368006);广西防灾减灾与工程安全重点实验室系统性研究项目(2014ZDX02)

摘要: 在爆炸、冲击等偶然荷载作用下,钢筋混凝土(RC)板柱结构中承重柱失效可能导致结构发生局部或整体连续倒塌破坏。为了研究板中配筋形式对RC板柱结构抗连续倒塌性能的影响,制作了两个1/3比例的楼盖子结构模型,通过单调静力加载试验研究了在角柱缺失条件下结构的连续倒塌性能。试验研究表明:,在混凝土板内配置连续上层钢筋可以有效减小板上裂缝的宽度;与板中采用非连续上层配筋的试件相比,采用连续配筋试件的屈服荷载、第一个峰值荷载和极限承载力分别提高了38.4%、31.8%和7.5%,在动力荷载作用下试件的抗倒塌能力也得到了明显提高;板中拉膜效应对于塑性铰线机制失效后结构的抗倒塌承载力贡献显著。

关键词: 钢筋混凝土, 板柱结构, 连续倒塌, 配筋形式, 拉膜效应

Abstract:

The local or global progressive collapse of reinforced concrete (RC) flat slab structures may occur due to the failure of load-bearing columns under the accidental loading, such as explosion and impact. In order to investigate the effect of slab reinforcement details on the progressive collapse performance of RC flat slab structures, two one-third scale RC flat slab substructure models are constructed and tested under monotonic static load in the scenario of loss of a corner column. Experimental results show that (1) continuous top slab reinforcement can effectively reduce the width of cracks on the slab; (2) as compared with the specimen with arranging discontinuous top slab reinforcement, the yield load, first peak load and ultimate bearing capacity of the substructure witharranging continuous top slab reinforcement increase respectively by 38.4%, 31.8% and 7.5%, and the progressive collapse resistance under dynamic load is significantly improved as well; and (3) the tensile membrane action in the slabs contributes significantlymake a significant contribution to the progressive collapse resistance after the working mechanism of yield lines fails.

Key words: reinforced concrete, flat slab structures, progressive collapse, reinforcement details, tensile membrane action