华南理工大学学报(自然科学版) ›› 2011, Vol. 39 ›› Issue (12): 94-99.

• 物理学 • 上一篇    下一篇

球形正十二面体声源测量近场HRTF 的误差

余光正 陈泽为   

  1. 华南理工大学 声学研究所,广东 广州 510640
  • 收稿日期:2011-05-24 修回日期:2011-07-12 出版日期:2011-12-25 发布日期:2011-11-04
  • 通信作者: 余光正(1978-) ,男,博士,讲师,主要从事心理声学与声信号处理研究. E-mail:scgzyu@scut.edu.cn
  • 作者简介:余光正(1978-) ,男,博士,讲师,主要从事心理声学与声信号处理研究.
  • 基金资助:

    国家自然科学基金青年基金资助项目( 11104082) ; 广东省自然科学基金资助项目( x2lxB6100320) ; 广东高校优秀青年创新人才培养计划资助项目( LYM10012) ; 华南理工大学中央高校基本科研业务费专项资金资助项目( 2011ZM0092)

Error of Near-Field HRTF Measured by Using Spherical Dodecahedral Sound Source

Yu Guang-zheng  Chen Ze-wei   

  1. Acoustic Laboratory,South China University of Technology,Guangzhou 510640,Guangdong,China
  • Received:2011-05-24 Revised:2011-07-12 Online:2011-12-25 Published:2011-11-04
  • Contact: 余光正(1978-) ,男,博士,讲师,主要从事心理声学与声信号处理研究. E-mail:scgzyu@scut.edu.cn
  • About author:余光正(1978-) ,男,博士,讲师,主要从事心理声学与声信号处理研究.
  • Supported by:

    国家自然科学基金青年基金资助项目( 11104082) ; 广东省自然科学基金资助项目( x2lxB6100320) ; 广东高校优秀青年创新人才培养计划资助项目( LYM10012) ; 华南理工大学中央高校基本科研业务费专项资金资助项目( 2011ZM0092)

摘要: 提出了球形正十二面体声源和球形头部的组合模型,利用球谐函数的多极展开和球基函数的旋转变换,得出该模型的双耳声压和近场头相关传输函数( HRTF) .然后用HRTF 的幅度谱误差分析球形正十二面体声源指向性和多重散射对近场HRTF 测量的共同影响.结果表明: 随着声源半径的减小和局部脉动单元半张角的增大,声源对近场HRTF 测量的影响减弱; 当声源距离不小于0. 2 m、声源半径不大于0. 025 m、局部脉动单元半张角不小于23. 6°时,声源误差主要出现在12 kHz 以上的频段; 除了异侧的个别方向,HRTF 的误差均控制在± 3. 5 dB 以内,可基本满足近场HRTF 的测量要求.最后自制了木质球模型和球形正十二面体声源,用个别方位测量得到的近场HRTF 数据验证了计算结果的合理性.

关键词: 球形正十二面体声源, 近场测量, 头相关传输函数, 多重散射, 指向性

Abstract:

In this paper,first,a combined model consisting of a spherical dodecahedral sound source and a spherical head model is established. Then,the binaural pressure and near-field head-related transfer function ( HRTF) are calculated via the multipole expansion of spherical harmonic functions and the rotation transform of spherical basis functions. Moreover,the common influences of the directivity and multiple scattering of the spherical dodecahedral sound source on the near-field HRTF measurement are analyzed according to the magnitude spectrum errors of HRTF. The results show that ( 1) the effects of sound source on near-field HRTF measurement weakens with the decrease in sound source radius and with the increase in half scan angle of each local pulsating unit; ( 2) when the sound source distance is not less than 0. 2m,the sound source radius is not more than 0. 025 m and the half scan angle is not less than 23. 6°,the errors resulting from the source generally appear at the frequencies more than 12 kHz; ( 3) except for some contralateral directions,the errors of HRTF are controlled within ± 3. 5dB,which basically satisfies the requirements of the near-field HRTF measurement. The proposed method is finally proved valid and applicable by the data measured in some particular directions with the help of a self-fabricated wood sphere and a practical spherical dodecahedron sound source.

Key words: spherical dodecahedron sound source, near-field measurement, head-related transfer function, multiple scattering, directivity

中图分类号: