华南理工大学学报(自然科学版) ›› 2005, Vol. 33 ›› Issue (11): 79-84.

• • 上一篇    下一篇

新型钢管混凝土板柱结构中柱节点抗震性能试验研究

林凡1 蔡健2 刘付钧2 吴源青2   

  1. 1.华南理工大学 建筑设计研究院,广东 广州 510640;2.华南理工大学 土木工程系,广东 广州 510640
  • 收稿日期:2004-11-15 修回日期:2005-09-05 出版日期:2005-11-25 发布日期:2005-11-25
  • 通信作者: 林凡(1970-),男,硕士,国家一级注册结构工程师,主要从事建筑结构设计研究 E-mail:2001linfan@21cn.com
  • 作者简介:林凡(1970-),男,硕士,国家一级注册结构工程师,主要从事建筑结构设计研究
  • 基金资助:

    广州市建设科技发展基金资助项目(200106)

Experimental Investigation into Anti-Seismic Behavior of a Novel Interior Slab-CFST Column Connection

Lin Fan1  Cai Jian2  Liu Fu-jun2  Wu Yuan-qing2   

  1. 1.Architecture Design and Research Institute,South China Univ.of Tech.,Guangzhou 510640,Guangdong,China;2.Dept.of Civil Engineering,South China Univ.of Tech,.Guangzhou 510640,Guangdong,China
  • Received:2004-11-15 Revised:2005-09-05 Online:2005-11-25 Published:2005-11-25
  • Contact: 林凡(1970-),男,硕士,国家一级注册结构工程师,主要从事建筑结构设计研究 E-mail:2001linfan@21cn.com
  • About author:林凡(1970-),男,硕士,国家一级注册结构工程师,主要从事建筑结构设计研究
  • Supported by:

    广州市建设科技发展基金资助项目(200106)

摘要: 对5个新型钢管混凝土板柱结构中柱节点的模型试件进行了低周反复荷载作用下的试验研究,分析并评价了不同配筋方式对其破坏形态、滞回特征及延性等抗震性能的影响.试验结果表明:新型钢管混凝土板柱节点在低周反复荷载作用下具有良好的受力性能,其构造方式能够满足“强柱弱板”的抗震设计原则;在柱上板带配置抗冲切箍筋能有效提高节点的抗震性能;无论是否配有抗冲切箍筋,弯曲破坏时节点的塑性变形能力和抗震性能均优于发生冲切破坏的节点.

关键词: 钢管混凝土柱, 板, 中柱节点, 抗震性能, 拟静力试验

Abstract:

The experiments of five scaled specimens with a novel interior slab-CFST (Concrete-Filled Steel Tubu-lar)column connection were carried out under low cyclic loading.The efects of different reinforcement arrange-ments on the failure mode,the anti-seismic behaviors including the hysteresis property and the ductility were then analyzed and evaluated.Test results show that the novel connection is of excellent performance under low cyclic loading,and that the construction form meets the anti-seismic design principles of strong column and weak slab.Moreover,reinforced stirrups in slab strips on the column can efectively improve the anti-seismic behavior of the connection,and,no matter whether the slab strips are reinforced with stirrups,the plastic deform ation capacity and anti-seismic behavior of the connection with flexural failure are all better than those of the connection with punching failure.

Key words: concrete-filled steel tubular column, slab, interior connection, anti-seismic behavior, quasi-static ex-periment