华南理工大学学报(自然科学版) ›› 2014, Vol. 42 ›› Issue (11): 92-98.doi: 10.3969/j.issn.1000-565X.2014.11.014

• 土木建筑工程 • 上一篇    下一篇

矩形螺旋箍筋约束波纹管浆锚连接装配式剪力墙抗震性能试验研究

刘家彬1 陈云钢1,2 郭正兴1 袁富1   

  1. 1.东南大学 土木工程学院,江苏 南京 210096; 2.安徽工业大学 建筑工程学院,安徽 马鞍山 243002
  • 收稿日期:2014-03-19 修回日期:2014-07-27 出版日期:2014-11-25 发布日期:2014-11-17
  • 通信作者: 刘家彬(1968-),男,博士,副教授,主要从事预制混凝土结构及施工技术研究. E-mail:dndxljb@126.com
  • 作者简介:刘家彬(1968-),男,博士,副教授,主要从事预制混凝土结构及施工技术研究.
  • 基金资助:

    “十二五”国家科技支撑计划项目(2011BAJ10B03)

Seismic Behavior of Precast Shear Wall with Rectangular Spiral Stirrups- Constraint Grouted Corrugated Pipe Connection

Liu Jia- bin1 Chen Yun- gang1,2 Guo Zheng- xing1 Yuan Fu1   

  1. 1.School of Civil Engineering,Southeast University,Nanjing 210096,Jiangsu,China; 2.School of Architectural Engineering,Anhui University of Technology,Maanshan 243002,Anhui,China
  • Received:2014-03-19 Revised:2014-07-27 Online:2014-11-25 Published:2014-11-17
  • Contact: 刘家彬(1968-),男,博士,副教授,主要从事预制混凝土结构及施工技术研究. E-mail:dndxljb@126.com
  • About author:刘家彬(1968-),男,博士,副教授,主要从事预制混凝土结构及施工技术研究.
  • Supported by:

    “十二五”国家科技支撑计划项目(2011BAJ10B03)

摘要: 为综合评价矩形螺旋箍筋约束波纹管浆锚连接的装配式混凝土剪力墙的抗震性能,对该剪力墙足尺试件进行了低周反复荷载试验,并与现浇试件进行对比.结果表明:矩形螺旋箍筋约束波纹管浆锚连接试件的破坏形态与现浇试件基本相同;由于水平拼缝的存在,两种试件的受力全过程的表现形式并不一致;两种试件的滞回曲线均较饱满,骨架曲线走势基本一致,耗能能力接近;两种试件的极限位移角分别为1/49 和1/45,位移延性系数均为4.0,满足延性要求;相比现浇试件,矩形螺旋箍筋约束波纹管浆锚连接试件各阶段的承载力有所降低.若水平拼缝采用合理构造,装配式混凝土剪力墙结构可以达到与现浇结构相当的延性、承载能力以及抗震耗能能力.

关键词: 预制混凝土, 装配式剪力墙, 螺旋箍筋, 波纹管浆锚, 抗震性能

Abstract:

In order to comprehensively evaluate the seismic behavior of the precast concrete shear wall with rectan- gular spiral stirrups- constraint grouted corrugated pipe connected to horizontal joints,the full- scale specimens of the shear wall was tested and compared with the cast- in- place specimens through a low- cycle loading experiment.The results show that the (1) the full- scale specimens follow the same failure pattern as the cast- in- place specimens do; (2) due to the existence of horizontal joints,the whole loading processes of the two kinds of specimens are diffe- rent; (3) the hysteresis curves of the two kinds of specimens are both full with similar skeleton curves,and the energy dissipation capacities are also similar; (4) the two kinds of specimens are of the ultimate displacement an- gles of 1/49 and 1/45 respectively,and the displacement ductility factors are both 4.0,which can meet the ductili- ty requirements; (5) the load capacities of the full- scale specimens at different stages are lower than that of the cast- in- place specimens; and (6) precast concrete shear wall with reasonable horizontal joints is of the ductility,load capacity and seismic energy dissipation capacity similar to those of the cast- in- place specimens.

Key words: precast concrete, precast shear wall, spiral stirrups, grouted corrugated pipe, seismic behavior