华南理工大学学报(自然科学版) ›› 2014, Vol. 42 ›› Issue (6): 114-120.doi: 10.3969/j.issn.1000-565X.2014.06.018

• 土木建筑工程 • 上一篇    下一篇

下沉广场对地下商业空间通风性能的影响

郭昊栩 邓孟仁 李颜   

  1. 华南理工大学 亚热带建筑科学国家重点实验室∥建筑学院,广东 广州 510640
  • 收稿日期:2014-02-17 修回日期:2014-03-26 出版日期:2014-06-25 发布日期:2014-05-01
  • 通信作者: 郭昊栩(1972-),男,博士,高级工程师,主要从事建筑设计及理论、建筑环境与人类行为及感觉等的研究. E-mail:hushkwok@126.com
  • 作者简介:郭昊栩(1972-),男,博士,高级工程师,主要从事建筑设计及理论、建筑环境与人类行为及感觉等的研究.
  • 基金资助:

    国家自然科学基金资助项目(51278193);亚热带建筑科学国家重点实验室开放课题(2013kb18);中国博士后科学基金资助项目(2012m521602);中国博士后科学基金特别资助项目(2013T60805);华南理工大学中央高校基本科研业务费专项资金资助项目(2014zz0021)

Effect of Sunken Plaza on Ventilation Performance of Underground Commercial Buildings

Guo Hao- xu Deng Meng- ren Li Yan   

  1. State Key Laboratory of Subtropical Building Science∥School of Architecture,South China University of Technology,Guangzhou 510640,Guangdong,China
  • Received:2014-02-17 Revised:2014-03-26 Online:2014-06-25 Published:2014-05-01
  • Contact: 郭昊栩(1972-),男,博士,高级工程师,主要从事建筑设计及理论、建筑环境与人类行为及感觉等的研究. E-mail:hushkwok@126.com
  • About author:郭昊栩(1972-),男,博士,高级工程师,主要从事建筑设计及理论、建筑环境与人类行为及感觉等的研究.
  • Supported by:

    国家自然科学基金资助项目(51278193);亚热带建筑科学国家重点实验室开放课题(2013kb18);中国博士后科学基金资助项目(2012m521602);中国博士后科学基金特别资助项目(2013T60805);华南理工大学中央高校基本科研业务费专项资金资助项目(2014zz0021)

摘要: 针对大型地下商业空间在机械通风方式下的发展局限性,选取位于广州地区的3 个在建的典型大型地下商业建筑为研究原型,以地下商业体的混合通风实现为切入点,探讨地下商业建筑的常见入口形式——下沉广场的方位选择对地下商业体内部通风环境的影响.根据设计原型抽象、建立具有一致性的分析模型,以 CFD 风环境模拟技术获取3 种模型状态下的速度矢量分布.在此基础上,对室内通风换气次数进行计算分析,并进一步运用 WeatherTool 软件进行区域热环境分析,从而获得热舒适及温、湿度组合均满足人体舒适要求的自然通风状态有效作用域范围.模拟实验结果表明:调整的下沉广场的方位及与中庭的相对位置关系,可改善自然通风的风速和均匀性,提升舒适感和能源效率;在广州地区,地层的吸热作用有利于改善地下商业空间的评价风速;设计中应结合通风性能的模拟来确定大型地下商业建筑的动线策略.

关键词: 下沉广场, 地下商业建筑, 混合通风, CFD 模拟

Abstract:

In order to overcome the development limitation of large- scale underground commercial buildings(UCBs) caused by mechanical ventilation mode,three large- scale UCBs being built in Guangzhou are taken as pro-totypes to discuss the interior ventilation of UCBs affected by the location of sunken plaza as a common entranceform of UCBs,with the implementation of hybrid ventilation as a point of penetration.Then,an analytical modelwith consistency is established through abstracting the prototypes,and the velocity vector distribution of airflow inthree model states is calculated via the CFD simulation of wind environment.Moreover,the interior air change rateof the samples is analyzed,and the regional thermal environment is discussed with WeatherTool,which helps to de-termine an effective domain of natural ventilation that fulfils the temperature and humidity requirements of humanbeing.Simulated results indicate that (1) suitable sunken plaza location and appropriate relative location of sunkenplaza to atrium may improve the air speed,airflow uniformity,comfortable sensation and energy efficiency in natu-ral ventilation state; (2) the heat absorption of fundamental parts helps to obtain a suitable air speed of UCBs inGuangzhou area; and (3) in the design of large- scale UCBs,ventilation simulation is necessary and beneficial.

Key words: sunken plaza, underground commercial building, hybrid ventilation, CFD simulation