收稿日期: 2014-06-16
修回日期: 2014-09-05
网络出版日期: 2014-11-17
基金资助
国家自然科学基金资助项目(51277191)
Analysis and Control of Unbalanced Load Compensation Capability of Cascaded STATCOM
Received date: 2014-06-16
Revised date: 2014-09-05
Online published: 2014-11-17
Supported by
国家自然科学基金资助项目(51277191)
唐治德 陈伟 罗建 邓明峰 . 链式 STATCOM 补偿不平衡负载分析及控制[J]. 华南理工大学学报(自然科学版), 2014 , 42(12) : 120 -126 . DOI: 10.3969/j.issn.1000-565X.2014.12.018
The cascaded STATCOM with delta configuration plays an important role in the unbalanced load compen-sation,and it is an important means to improve power quality.In this paper,through theoretical analysis,a methodof calculating the compensation range of negative sequence current is proposed for compensating the rated reactivecurrent by using the cascaded 10kV·A/(380V) STATCOM with delta configuration.As the individual phase con-trol of the cascaded STATCOM with delta configuration shows a slow dynamic response and a low precision,the in-dividual sequence control is adopted to handle the cascaded STATCOM with delta configuration,thus realizing acomprehensive compensation for reactive and negative sequence components.Finally,in the Matlab/Simulink envi-ronment,a 10kV·A/(380V) STATCOM with delta configuration is built to simulate the system,and the resultsprove the correctness of the calculation method and the control strategy.
/
| 〈 |
|
〉 |